VHF1 (2)(3) EMITTING
When a VHF transceiver (XCVR) emits for more than 60 seconds, the
master caution light comes on amber, the single chime sounds and a message appears on the upper ECAM display unit.
When a VHF transceiver (XCVR) emits for more than 60 seconds, the
master caution light comes on amber, the single chime sounds and a message appears on the upper ECAM display unit.
HF1 (2) EMITTING (OPTION)
When an HF XCVR, if installed, emits for more than 60 seconds, the master caution light comes on amber, the single chime sounds and a message appears on the upper ECAM display unit.
When an HF XCVR, if installed, emits for more than 60 seconds, the master caution light comes on amber, the single chime sounds and a message appears on the upper ECAM display unit.